Siemens

MV Switchgear Installation Engineer- Abu Dhabi, UAE

Abu Dhabi, UAEPosted 1 weeks ago

Apply link checked today

Salary
AED 12k–18k a month· est.
Job type
Full time
Level
Senior
Field
Energy & Sustainability
Work mode
On site

About the role

MV Switchgear Installation Engineer / Abu Dhabi, UAE Siemens strongly believes in the value of a Digital Portfolio; hence Smart Infrastructure combines Digital Power Distribution and Digital Building Infrastructure technologies. Our Digital Portfolio will enable our customers to enjoy occupants’ intuitive buildings which are comfortable, safe, secure and energy efficient. Smart infrastructure from Siemens intelligently connects energy systems, buildings and industries to adapt and evolve the way we live and work. We work together with customers and partners to build an ecosystem that intuitively responds to the needs of people and helps customers to better use resources. It helps our customers to thrive, communities to progress and supports sustainable development. Join our Smart Infrastructure, Electrification & Automation division as the MV Switchgear Installation Engineer and help us re-imagine the world by finding solutions and making the world a smarter place for tomorrow. Your Role – International, Challenging And Future-Oriented! In this role you will be based in Abu Dhabi, UAE & carrying out Installation, Maintenance, Retrofitting, Modification, Extension, Troubleshooting of Siemens MV Switchgears GIS, AIS, LVAC in UAE / Oman / Bahrain / Saudi Arabia / Qatar / Kuwait - Installation of MV Switchgear up to 33kV GIS, Torque Test, Mechanical operation checks for TPS, Disconnector, Earth Switch, CRM Test, Vacuum, SF6 gas filling & quality checks after installation, attending & closing NCRs observed during installation. Receipt of final installation certificate from consultant / end customer. Knowledge on SF6 handling & Test equipments such as DILO, SF6 gas analyzer, SF6 leak detector etc. is must. - Installation of MV Switchgear up to 33kV AIS, Torque Test, Mechanical operation checks, CRM Test after installation, attending & closing NCRs faced at site during installation. Receipt of final installation certificate from consultant / end customer - Installation of LV Switchgear up to 440V, Torque Test, Mechanical operation checks, CRM Test after installation, attending & closing NCRs faced at site during installation. Receipt of final installation certificate from consultant / end customer - Troubleshooting for SF6 gas leaks / gas quality, Mechanical issues in GIS - Troubleshooting Mechanical issues in AIS, LV Switchgears - Extension, Modification, Retrofitting of MV Switchgear GIS, AIS & LVAC - CT replacement, Cable housing, Bus bar housing replacement in GIS - Preventive & corrective Maintenance of GIS, AIS, LVAC Switchgears - Preparation of Installation SAT Protocols - Preparation of detailed Method statements, Risk Assessments with respect to primary / secondary systems isolation with electrical single line diagram for various switchgear extension, modification, retrofitting, troubleshooting, corrective, preventive maintenance & other critical jobs in energized sub station - Conducting SAT with Customers for Switchgear Installation & final handover to commissioning team - Feedback on Product issues, identification & rectification of NCRs - Customer presentation and Fault / Root Cause Analysis - Knowledge of Switchgear Primary Components Testing & Commissioning such as CTs, VTs, Circuit Breakers, Disconnectors, Vaccum Bottle Integrity Test etc. & conducting High Voltage Test on Switchgear will be an added advantage - Reporting to Local Team Head / Team Lead for Switchgear Installation & Commissioning activities on various jobs Your Qualifications and Skills – Digital And Solid! - Minimum Bachelor of Engineering (Electrical) - Working experience in Multicultural environment. Installation & Commissioning of MV / LV Switchgear & its components preferably in Middle East with experience between 5 to 8years. - Training on Siemens GIS / AIS / LVAC Switchgear Products / Systems preferred - Must be familiar with Siemens Switchgears GIS 8DA10, 8DB10, NX Pls C / AIS NX Air, NX Air H, SIMOPRIME / LVAC SIVACON etc. - Technical Product knowhow - Thorough knowledge of SF6 gas handling & filling equipments especially DILO, SF6 Analyzer, Leak detector, GDM Calibration, Floor Level checker, Microohm Meter, High Voltage Test, CB Analyzer, CT Analyzer etc. - Familiarity with New Technologies such as Blue GIS - Knowledge on Competitor Products - Self-motivated and be a team Player with effective Communication Skills - Language skills English What else do you need to know? As a world leader in developing and producing the most advanced engineering technologies, we improve lives and further human achievements worldwide, while also protecting the climate - all thanks to our employees. Working with us, you have the foundation to develop personally and professionally. We give you the chance to do something significant that benefits society and human progress. We give you the chance to create a difference. Diversity at Siemens is our source of creativity and innovation. Having different types of talent and experiences makes us

Requirements

Minimum Bachelor of Engineering (Electrical). Working experience in multicultural environment. Installation & Commissioning of MV / LV Switchgear & its components preferably in Middle East with experience between 5 to 8 years. Training on Siemens GIS / AIS / LVAC Switchgear Products / Systems preferred. Must be familiar with Siemens Switchgears GIS 8DA10, 8DB10, NX Pls C / AIS NX Air, NX Air H, SIMOPRIME / LVAC SIVACON etc. Technical Product knowhow. Thorough knowledge of SF6 gas handling & filling equipments especially DILO, SF6 Analyzer, Leak detector, GDM Calibration, Floor Level checker, Microohm Meter, High Voltage Test, CB Analyzer, CT Analyzer etc. Familiarity with New Technologies such as Blue GIS. Knowledge on Competitor Products. Self-motivated and be a team Player with effective Communication Skills. Language skills English.

Responsibilities

  • Installation of MV Switchgear up to 33kV GIS, Torque Test, Mechanical operation checks for TPS, Disconnector, Earth Switch, CRM Test, Vacuum, SF6 gas filling & quality checks after installation, attending & closing NCRs observed during installation. Receipt of final installation certificate from consultant / end customer. Knowledge on SF6 handling & Test equipments such as DILO, SF6 gas analyzer, SF6 leak detector etc. is must.
  • - Installation of MV Switchgear up to 33kV AIS, Torque Test, Mechanical operation checks, CRM Test after installation, attending & closing NCRs faced at site during installation. Receipt of final installation certificate from consultant / end customer
  • - Installation of LV Switchgear up to 440V, Torque Test, Mechanical operation checks, CRM Test after installation, attending & closing NCRs faced at site during installation. Receipt of final installation certificate from consultant / end customer
  • - Troubleshooting for SF6 gas leaks / gas quality, Mechanical issues in GIS
  • - Troubleshooting Mechanical issues in AIS, LV Switchgears
  • - Extension, Modification, Retrofitting of MV Switchgear GIS, AIS & LVAC
  • - CT replacement, Cable housing, Bus bar housing replacement in GIS
  • - Preventive & corrective Maintenance of GIS, AIS, LVAC Switchgears
  • - Preparation of Installation SAT Protocols
  • - Preparation of detailed Method statements, Risk Assessments with respect to primary / secondary systems isolation with electrical single line diagram for various switchgear extension, modification, retrofitting, troubleshooting, corrective, preventive maintenance & other critical jobs in energized sub station
  • - Conducting SAT with Customers for Switchgear Installation & final handover to commissioning team
  • - Feedback on Product issues, identification & rectification of NCRs
  • - Customer presentation and Fault / Root Cause Analysis
  • - Knowledge of Switchgear Primary Components Testing & Commissioning such as CTs, VTs, Circuit Breakers, Disconnectors, Vaccum Bottle Integrity Test etc. & conducting High Voltage Test on Switchgear will be an added advantage
  • - Reporting to Local Team Head / Team Lead for Switchgear Installation & Commissioning activities on various jobs

Skills

  • MV Switchgear installation
  • 33kV GIS
  • 33kV AIS
  • LV Switchgear installation
  • SF6 gas handling
  • DILO
  • SF6 gas analyzer
  • SF6 leak detector
  • Vacuum integrity tests
  • High Voltage Testing
  • CMR/Test procedures
  • NCR closing
  • Method statements
  • Risk Assessments
  • SAT (Site Acceptance Testing)